HI 96733
Ammonia, High Range, Portable Photometer
- CAL CHECK™
- User calibration
- Certified calibration and verification standards
- BEPS (Battery Error Prevention System)
- TIMER function
- Auto shut-off
- GLP Features
This meter uses an exclusive positive-locking system to ensure that the cuvette is in the same place every time it is placed into the measurement cell.
Ammonia is often an excellent indication of the presence of animal or plant microbiological decay. It is tested in fish farms (fresh and salt water tanks) due to the damaging effects of its toxic nature. Its presence in rivers and reservoirs normally points to agricultural and/or civil pollutants. Ammonia is tested in lakes, rivers, portable water, boiler feed water, sewage, industrial and waste water.
Order Information:
HI 96733 is supplied with sample cuvettes with caps (2), 9V battery and instruction manual.
HI 96733C includes photometer, sample cuvettes with caps (2 ea.), 9V battery, cloth for wiping cuvettes, instrument quality certificate, instruction manual and rigid carrying case.
Specification :
Range | : | 0.0 to 50.0 mg/L (ppm) |
Resolution | : | 0.1 mg/L |
Accuracy | : | ±0.5 mg/L ±5% of reading @ 25°C |
Light Source | : | Tungsten Lamp |
Light Detection | : | silicon photocell with narrow band interference filter @ 420 nm |
Power Supply | : | 9V battery |
Environment | : | 0 to 50°C (32 to 122°F); RH max 95% non-condensing |
Dimensions | : | 192 x 104 x 69 mm (7.6 x 4.1 x 2.7") |
Weight | : | 360 g (12.7 oz.) |
Method | : | adaptation of the ASTM Manual of Water and Environmental Technology, D1426-92, Nessler method |
Solutions | |
---|---|
HI 93703-50 | Cuvette Cleaning Solution |
Accessories | |
HI 731321 | Glass Cuvette Set |
HI 731331 | Glass Cuvette Set |
HI 731335 | Cuvette Cap for HI 957xx Series Meters |
HI 731318 | Cuvette Cleaning Cloth |
Reagents & Standards | |
HI 93733-01 | Ammonia HR, Nessler Method (100 Tests) |
HI 93733-03 | Ammonia HR, Nessler Method (300 Tests) |
http://www.hannainst.com/manuals/man96733_19_03_2012.pdf
Untuk Pemesanan segera hubungi :
Contact : Aditya Kurniawan
Office : 021-7865365
Mobile : 02199317739 / 085716241676 / 082110947526
email : adit.solusitech@gmail.com, adit.solusindotech@gmail.com, sales@solusitech.com
YM : adit_solusitech
Indonetwork : solusitech.indonetwork.co.id, solusindo_technology.indonetwork.co.id
Indotrading : solusindotechnology.web.indotrading.com
Blog : solusindotechnology.blogspot.com
Website : www.solusitech.com
Alamat : Jl. M. Kahfi 1 Gg. Asem RT10 RW4 No. 65 Kel. Cipedak - Jagakarsa , Jakarta Selatan 12560
Tidak ada komentar:
Posting Komentar