W-800 Benefits
  • Customization is now a breeze
  • Modular software upgrading path grows with you
    and your applications
  • From Entry Level: for the occasional user to the more demanding
    survey tasks of the advanced users

Pentax Solution Partner
Pentax Solution Partner Many survey challenges, one logical solution: OPEN PLATFORM
By collaborating with selected Software Solution Partner, MicroSurvey, Pentax can offer a broad range of functionalities to cover almost every specific task.
Extended EDM Performance
Measures distances in reflectorless mode over 550m and over 7000m to a single prism while maintaining the same high level of accuracy.
Benefits: Its extended measuring range prevents you of making additional instrument setups.

Pentax’s exclusive Auto Focus system
Benefits: Always an instant razor sharp image.

More Flexibility Faster Turnaround
Connectivity: In its standard configuration, the Pentax W-800 is equipped with multiple data-interfaces (mini-USB data port, CF-card slot and SD-card slot, RS-232C data port) providing seamless data-transfer to a PC or laptop for further data processing.

Tri-axis correction
The W-822NX and W-823NX models feature a unique precision Tri-axis correction to provide automatic error compensation, in addition to dualaxis correction.The error occurs where the vertical, horizontal and sight axis intersect.

Specification :
Model W-800 W-822NX
Telescope Magnification 30 x
Effective aperture 45 mm (EDM 45 mm)
Resolving power 3.0”
Field of view 2.6 % (1°30’)
Minimum focus 1.0 m
Focus Auto focus / Power focus / Manual
Distance measurement Laser class Visible laser: Class III a (3R) (Reflectorless) / Class II (2) (Prism, sheet)
Measurement range Reflectorless (*1) 1.5 ~550 m
(Good conditions) (*3) Reflector sheet (*2) 1.5 ~ 600 m (800 m)
Mini prism 1.5 ~ 2500 m (3000 m)
1P 1.5 ~ 7000 m (9000 m)
3P 1.5 ~ 9000 m (9999 m)
Accuracy (*4) Prism / Reflector sheet ± (2 + 2 ppm x D) mm
Reflectorless 1.5 ~ 300 m: ± (5 + 2 ppm x D) mm / 300 m ~: ± (7 + 10 ppm x D) mm
At Auto-ATM. Correction
Prism / Reflector sheet ± (2 + 10 ppm x D) mm
Reflectorless 1.5 ~ 300 m: ± (5 + 10 ppm x D) mm / 300 m ~: ± (7 + 18 ppm x D) mm
Minimum count 0.1 mm (Fine mode) / 1 mm (Normal mode) / 10mm (Track mode)
Meassuring time (*5) Repeat meas.         Normal (1 mm) Prism / Reflector sheet 2.0 sec - Reflectorless 2.0 sec
Quick (1 mm) Prism / Reflector sheet 1.2 sec (*6)
Track (10 mm) Prism / Reflector sheet 0.4 sec - Reflectorless 0.4 sec
Initial meas.           Normal (1 mm) Prism / Reflector sheet 2.5 sec - Reflectorless 2.4 sec
Quick (1 mm) Prism / Reflector sheet 1.7 sec (*6)
Track (10 mm) Prism / Reflector sheet 2.5 sec - Reflectorless 2.5 sec
Angle measurement Measurement method Absolute rotary encoder
Detection method Vertical / horizontal angle: 2 sides
Minimum count 0.5”/1”/5” selectable
Accuracy (ISO 17123-3) 2”
Compensator 3 Axis (*7)
Target screw 2 speed
Sensitivity of vials Plate level (electronic) 30” / 1 div.
Circular level 8’ / 2 mm
Laser Plummet Visible laser: ± 0.5mm (instrument height: 1.5m) (Optical Plummet is optional)
Base Detachable
Dust & water resistance IP54 (instrument only)
Ambient temperature -20°C ~ +50°C / -4°F ~ 122°F (working range)
Tripod thread 5/8” x 11
Dimensions / Weight Dimensions 197 (W) x 347 (H) x 217 (L) mm
Weight (incl. battery) 6.3 kg
Carrying case 380 (W) x 292 (H) x 475 (L) mm / 3.2 kg
Battery pack BP02 Power source Ni-MH 4300 mAh (rechargeable) DC 6.0 V
Operation time Approx. 7 hrs (single measurement every 30 seconds)
Weight 380 g
Battery charger BC03 Input Voltage (AC01) AC 100 ~ 240 V
and AC adapter AC 01 Output Voltage (BC03) DC 7.5 V
Weight 280 g
Data Process CPU, Clock frequency Intel® - XScale, 400 MHz
OS Microsoft® - Windows® CE 4.2
Application software Selectable
Internal memory SDRAM = 64 MB / FLASH = 128MB (built-in)
Memory card 2GB (Max) (*8)
I / F RS-232C, CF Type II, SD CARD, USB
Display / keyboard Display type 3.7 inch - Color LCD, 640 x 480 pixels (*9) with back light and touch panel function
Quantity 2
Keys 33 each (12 numeric / 11 function / 10 special)
Display back light Intensity settings: 10 steps
Laser Pointer Yes
Date clock Yes
*1 The measurement range and accuracy of reflectorless, and time required to
measure may vary by the shape, size of surface area and reflection rate of the
target and its environment. The measurement range of reflectorless is
determined by the white side of the Kodak Gray Card.
*2 Reflector sheet: PENTAX genuine Reflector sheet
*3 The measurement range may vary by conditions of the environment. Normal
conditions: 20 km visibility with slight shimmer. Good conditions:
40 km visibility, overcast, no heat, no shimmer and moderate wind.
*4 When automatic atmospheric correction is on, the EDM error is 10 ppm in
prism and reflector sheet mode.
*5 EDM measuring time is determined in good conditions. It may takes longer
than usual to measure the distance exceeding 4000 m in prism mode and 300
m in reflectorless mode.
*6 Quick mode, which functions with prism and reflector sheet, is effective only
under normal mode (1 mm) and up to 500 m.
*7 In addition to dual-axis correction in the (X) and (Y) direction, mechanical error
in the instrument is corrected.
*8 Memory card is not supplied with the instrument.
*9 Depending on application software.


Untuk Pemesanan segera hubungi :
Contact : Aditya Kurniawan
Office : 021-7865365
Mobile : 02199317739 / 085716241676 / 082110947526
email : adit.solusitech@gmail.com, adit.solusindotech@gmail.com, sales@solusitech.com
YM : adit_solusitech
Indonetwork : solusitech.indonetwork.co.id, solusindo_technology.indonetwork.co.id
Indotrading : solusindotechnology.web.indotrading.com
Blog : solusindotechnology.blogspot.com
Website : www.solusitech.com
Alamat : Jl. M. Kahfi 1 Gg. Asem RT10 RW4 No. 65 Kel. Cipedak - Jagakarsa , Jakarta Selatan 12560

Tidak ada komentar:

Posting Komentar