HI 96710
Free and Total Chlorine and pH Portable Photometer
- CAL CHECK™
- User calibration
- Certified calibration and verification standards
- BEPS (Battery Error Prevention System)
- TIMER function
- Auto shut-off
- GLP Features
HANNA has developed the HI 96710 to measure pH, free chlorine and total chlorine — three critical parameters to ensure good water quality.
Order Information:
HI 96710 is supplied with sample cuvettes with caps (2), 9V battery and instruction manual.
HI 96710C includes HI 96710 photometer, hard carrying case, 2 sample cuvettes, scissors, cuvette cleaning cloth, battery and instruction manual.
Specifications :
| Range | pH | 6.5 to 8.5 pH |
| Cl, Free | 0.00 to 5.00 mg/L (ppm) | |
| Cl, Total | 0.00 to 5.00 mg/L (ppm) | |
| Resolution | pH | 0.1 pH |
| Cl, Free | 0.01 mg/L | |
| Cl, Total | 0.01 mg/L | |
| Accuracy @25°C | pH | ±0.1 pH |
| Cl, Free | ±0.03 mg/L ±3% of reading | |
| Cl, Total | ±0.03 mg/L ±3% of reading | |
| Light Source | tungsten lamp | |
| Light Detector | silicon photocell with narrow band interference filter @ 525 nm | |
| Power Supply | 9V battery | |
| Auto-off | after ten minutes of non-use in measurement mode; after one hour of non-use in calibration mode; with last reading reminder | |
| Environment | 0 to 50°C (32 to 122°F); RH max 95% non-condensing | |
| Dimensions | 192 x 104 x 69 mm (7.6 x 4.1 x 2.7") | |
| Weight | 360 g (12.7 oz.) | |
| Method | pH | Phenol Red method |
| Chlorine | adaptation of the EPA recommended DPD method 330.5 |
Accessories :
| Solutions | |
|---|---|
| HI 93703-50 | Cuvette Cleaning Solution |
| Accessories | |
| HI 731331 | Glass Cuvette Set |
| HI 731335 | Cuvette Cap for HI 957xx Series Meters |
| HI 731318 | Cuvette Cleaning Cloth |
| Reagents & Standards | |
| HI 93701-01 | Chlorine, free, DPD Method (100 Tests) |
| HI 93701-03 | Chlorine, free, DPD Method (300 Tests) |
| HI 96710-11 | CAL CHECK™ standard cuvettes(pH) |
| HI 93710-01 | pH, Phenol Red Method (100 Tests) |
| HI 93710-03 | pH, Phenol Red Method (300 Tests) |
| HI 96711-11 | Cal Check® Standard cuvette for HI 96711 |
| HI 93711-01 | Chlorine, Total, DPD Method (100 Tests) |
| HI 93711-03 | Chlorine, Total, DPD Method (300 Tests) |
Untuk Pemesanan segera hubungi :
Contact : Aditya Kurniawan
Office : 021-7865365
Mobile : 02199317739 / 085716241676 / 082110947526
email : adit.solusitech@gmail.com, adit.solusindotech@gmail.com, sales@solusitech.com
YM : adit_solusitech
Indonetwork : solusitech.indonetwork.co.id, solusindo_technology.indonetwork.co.id
Indotrading : solusindotechnology.web.indotrading.com
Blog : solusindotechnology.blogspot.com
Website : www.solusitech.com
Alamat : Jl. M. Kahfi 1 Gg. Asem RT10 RW4 No. 65 Kel. Cipedak - Jagakarsa , Jakarta Selatan 12560
.jpg)
Tidak ada komentar:
Posting Komentar