Industry standard, CL17 Free Chlorine Analyzer. Included with the
CL17 analyzer is a 1 month supply of DPD indicator and Free Chlorine
indicator and buffer solutions, an installation kit, sample conditioning
kit, maintenance kit, and a user manual. *This product has not been
evaluated to test for chlorine and chloramines in medical applications
in the United States.
- Accurate, Reliable Results
- Simple, Predictable Maintenance
- Factory Calibrated
- EPA Compliant
- Pump Control
Accurate, Reliable Results
The Hach CL17 Chlorine Analyzer uses colorimetric DPD
chemistry to monitor water continuously for free or total residual
chlorine. The CL17 is a simple, dependable and economic solution, and
the preferred choice to high-maintenance instruments that require
frequent calibration. The CL17 analysis method is robust and not
affected by changes in chlorine concentration, sample pH, temperature,
flow, or pressure, thus offering more accuracy and reliability than
alternative instruments and technologies.
Simple, Predictable Maintenance
Monthly routine maintenance for the CL17 can typically
be performed in 15 minutes and includes changing reagents and cleaning
the colorimetric cell. No special tools are required. For typical use,
the CL17 will operate unattended for 30 days. Challenging applications
may require more frequent cleaning.
Factory Calibrated
The CL17 Chlorine Analyzer is factory calibrated. A
built-in electronic calibration curve is preprogrammed into the
instrument. This instrument does not require recalibration unless
specified by your regulatory agency for compliance reporting purposes.
EPA Compliant
The CL17 is compliant with US EPA regulation 40 CFR
140.74, and both Method 4500-CL G and Method 334.0 can be used for
measurement of residual chlorine in drinking water.
Pump Control
Both an alarm for manual chlorine feed control and a
4-20 mA output for automatic control of chlorine feed pumps is available
on the CL17 Analyzer.
What's in The Box :
Hach CL17 Chlorine Analyzer, a one-month supply of
reagents, Sulfuric acid, Maintenance kit, Installation kit, and Manual.
(The power cord is ordered separately.)
Specification :
Accuracy: | ± 5 % or ±0.03 mg/L (ppm) as CL2, whichever is greater |
Air Purge: | 0.1 cfm (0.17 m³/h) instrument quality air at max. 20 psig (ca. 1.4 bar) |
Alarm: | Two alarms selectable for sample concentration alarm, analyzer system warning, or analyzer system shut-down alarm. Each is equipped with an APDT relay with contacts rated for 5A resistive load at 230 V AC. |
Certifications: | EN 61326-1:06 CISPR 11 Class A Emissions Limits EN 61010-1: 10 IEC 60529 for IP62 Enclosure UL 61010A-1 CAN/CSA C22.2 NO. 1010.1-92 |
Cycle Time: | 2.5 minutes |
Dimensions (H x W x D): | 37.1 in x 16.5 in x 7.5 in (943 mm x 419 mm x 191 mm) |
Display: | LCD, 3-1/2 inch digit measurement readout and six-character alphanumeric scrolling text line |
Drain: | 1/2-inch ID flexible hose, hose barb |
Enclosure Construction: | ABS plastic, two clear polycarbonate windows, IP62-rated with the gasketed door latched. |
Inlet: | 1/4-inch OD polyethylene tube, quick-disconnect fitting |
Interferences: | Other oxidizing agents such as bromide, chlorine dioxide, permanganate and ozone will cause a positive interference. Hexavalent chromium will cause a positive interference: 1 mg/L Cr⁶⁺ = approximately 0.02 mg/L as Cl₂. Hardness must not exceed 1,000 mg/L as CaCO₃. |
Light Source: | Class 1 LED (light emitting diode) with a peak wavelength of 520 nm; 50,000 hours estimated minimum life |
Lower Limit of Detection (LOD): | 0.02 mg/L (ppm) |
Mounting: | Wall mount |
Operating Humidity: | 90% at 40 °C (90% at 104 °F) maximum |
Operating Temperature Range: | 5 to 40 °C (41 to 104 °F) |
Power Requirements (Amps): | 2.5 A |
Power Requirements (Hz): | 50/60 Hz |
Power Requirements (Voltage): | 100 - 115/230 V AC |
Pressure Limit: | Inlet Pressure to Sample Conditioning 1.5 to 75 psi (0.1 bar to 5.2 bar) |
Range: | 0 to 5 free or total residual chlorine |
Ranges: | 0 to 5 mg/L free or total residual chlorine |
Repeatability: | 0.01 ppm or 3.0 % , whichever is greater |
Sample Flow Rate: | 200 to 500 mL per minute minimum required |
Sample Temperature: | 5 to 40 °C (41 to 104°F) |
Weight: | 24.91 lbs. (11.3 kg) |
Optional Accessories
Untuk Pemesanan segera hubungi :
Contact : Aditya KurniawanOffice : 021-7865365
Mobile : 02199317739 / 085716241676 / 082110947526
email : adit.solusitech@gmail.com, adit.solusindotech@gmail.com, sales@solusitech.com
YM : adit_solusitech
Indonetwork : solusitech.indonetwork.co.id, solusindo_technology.indonetwork.co.id
Indotrading : solusindotechnology.web.indotrading.com
Blog : solusindotechnology.blogspot.com
Website : www.solusitech.com
Alamat : Jl. M. Kahfi 1 Gg. Asem RT10 RW4 No. 65 Kel. Cipedak - Jagakarsa , Jakarta Selatan 12560
Tidak ada komentar:
Posting Komentar