HI 96715
Ammonia, Medium Range, Portable Photometer
- CAL CHECK™
- User calibration
- Certified calibration and verification standards
- BEPS (Battery Error Prevention System)
- TIMER function
- Auto shut-off
- GLP Features
These meters use an exclusive positive-locking system to ensure that the cuvette is in the same place every time it is placed into the measurement cell.
Ammonia is often an excellent indication of the presence of animal or plant microbiological decay. It is tested in fish farms (fresh and salt water tanks) due to the damaging effects of its toxic nature. Its presence in rivers and reservoirs normally points to agricultural and/or civil pollutants. Ammonia is tested in lakes, rivers, portable water, boiler feed water, sewage, industrial and waste water.
Order Information:
HI 96715 is supplied with sample cuvettes with caps (2), 9V battery and instruction manual.
HI 96715C includes photometer, sample cuvettes with caps (2 ea.), 9V battery, cloth for wiping cuvettes, instrument quality certificate, instruction manual and rigid carrying case.
Specification :
Range | : | 0.00 to 9.99 mg/L (ppm) |
Resolution | : | 0.01 mg/L (ppm) |
Accuracy | : | ±0.05 mg/L ±5% of reading @ 25°C |
Light Detector | : | Silicon Photocell with narrow band interference filter @ 466 nm |
Light Source | : | Light Emitting Diode |
Environment | : | 0 to 50°C (32 to 122°F); Max 95% RH non-condensing |
Battery Type | : | 9V |
Auto Shut-off | : | after ten minutes of non-use in measurement mode; after one hour of non-use in calibration mode; with last reading reminder |
Dimensions | : | 192 x 104 x 69 mm (7.6 x 4.1 x 2.7") |
Weight | : | 360 g (12.7 oz.) |
Method | : | adaptation of the ASTM Manual of Water and Environmental Technology, D1426-92, Nessler method |
Solutions | |
---|---|
HI 93703-50 | Cuvette Cleaning Solution |
Accessories | |
HI 731318 | Cuvette Cleaning Cloth |
HI 731331 | Glass Cuvette Set |
HI 731335 | Cuvette Cap for HI 957xx Series Meters |
Reagents & Standards | |
HI 93715-01 | Ammonia MR, Nessler Method (100 Tests) |
HI 93715-03 | Ammonia MR, Nessler Method (300 Tests) |
HI 95715-11 | Cal Check® Standard cuvette for HI 95715 |
http://www.hannainst.com/manuals/man96715_27_07_10.pdf
Untuk Pemesanan segera hubungi :
Contact : Aditya Kurniawan
Office : 021-7865365
Mobile : 02199317739 / 085716241676 / 082110947526
email : adit.solusitech@gmail.com, adit.solusindotech@gmail.com, sales@solusitech.com
YM : adit_solusitech
Indonetwork : solusitech.indonetwork.co.id, solusindo_technology.indonetwork.co.id
Indotrading : solusindotechnology.web.indotrading.com
Blog : solusindotechnology.blogspot.com
Website : www.solusitech.com
Alamat : Jl. M. Kahfi 1 Gg. Asem RT10 RW4 No. 65 Kel. Cipedak - Jagakarsa , Jakarta Selatan 12560
Tidak ada komentar:
Posting Komentar